Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Cont Lens Anterior Eye ; 45(2): 101440, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33814283

RESUMO

PURPOSE: To determine the impact of different central optical zone diameters (COZDs), obtained from pupil size, on the visual performance of presbyopic subjects fitted with centre-distance simultaneous-image multifocal contact lenses (SIMCLs). METHODS: Thirty-two presbyopic volunteers, between 45-58 years of age, participated in this prospective, controlled, double-blind study. Subjects were fitted with 5 centre-distance SIMCLs of variable COZD, determined from the measurement of pupil size under photopic light conditions and corresponding to 60, 70, 80, 90 and 100 % of pupil diameter. Subjects visual performance was evaluated through the measurement of distance, intermediate and near visual acuity (VA), "visual functional range" (VFR) obtained from the VA Defocus Curve (VADC) and Contrast Sensitivity Function (CSF), using a third-generation retina display iPad. RESULTS: Statistically significant differences were obtained for both distance (p = 0.01) and intermediate (p = 0.001) VA amongst designs. Best results were obtained with 80 % and 90 % COZDs compared to 60 %. No significant differences in VFR (p > 0.05) were obtained amongst the different COZDs. 90 and 100 % COZDs offered statistically significant better results at 6 and 18 cycles per degree (cpd) in the CSF, compared to the 60 and 70 % designs. CONCLUSIONS: SIMCLs with COZDs of 80-90 % and of 90-100% of photopic pupil diameter offered better distance and intermediate VA, without a decline in near performance, and superior contrast sensitivity at medium and high spatial frequencies respectively, compared to lower COZD designs.


Assuntos
Lentes de Contato , Pupila , Sensibilidades de Contraste , Método Duplo-Cego , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Acuidade Visual
2.
J Fr Ophtalmol ; 45(1): 20-27, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34840000

RESUMO

OBJECTIVES: This study aims to evaluate the relationship between application of the MGDRx thermal eyebag and dry eye signs and symptoms in young and older subjects and to compare the results between the two groups. METHODS: Thirty young, healthily volunteers between 18 and 31 years of age (23.95±3.94 years) and thirty older subjects between 61 and 90 years of age (77.97±8.11 years) participated in this study. Ocular surface parameters were assessed using the Oculus Keratograph 5M, following the guidelines of the Tear Film and Ocular Surface Dry Eye Workshop II Diagnostic Methodology report. Only subjects with a positive score on at least one questionnaire and an initial Non-Invasive Keratograph Break-Up Time (NIKBUT) under 10seconds were included in the study. After thermal bag self-application in both eyes every day for 2 weeks, the protocol was carried out again. Lid massage was performed after lid warming. Compliance and degree of improvement were also assessed. MAIN RESULTS: The young volunteer group showed an improvement in NIKBUT, lipid layer score, upper eyelid gland drop-out percentage and dry eye symptoms over the two week treatment period. Improvements in meibum quality, gland obstruction, telangiectasia scores, and dry eye symptoms were found in the older subjects. Mixed ANOVA revealed better NIKBUT and lipid layer values in the young subjects. Despite the treatment compliance being statistically higher in the older group than in the younger subjects (P=0.002), there were no significant differences in subjective improvement between groups (P=0.097). CONCLUSION: Dry eye-related symptoms were improved after thermal bag application, while NIKBUT and lipid layer thickness were improved only in the younger subjects.


Assuntos
Síndromes do Olho Seco , Adulto , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/terapia , Pálpebras , Humanos , Lipídeos , Glândulas Tarsais , Inquéritos e Questionários , Lágrimas , Adulto Jovem
3.
Graefes Arch Clin Exp Ophthalmol ; 258(12): 2701-2714, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32524240

RESUMO

PURPOSE: The objective of this study was to analyze the differences in blinking kinematics of spontaneous and voluntary blinks using for the first time a self-developed, non-invasive, and image processing-based method. METHODS: The blinks of 30 subjects were recorded for 1 min with the support of an eye-tracking device based on a high-speed infrared video camera, working at 250 frames per second, under two different experimental conditions. For the first condition, subjects were ordered to look in the straightforward position at a fixation target placed 1 m in front of them, with no further instructions. For the second, subjects were additionally asked to blink only following a sound signal every 6 s. RESULTS: Mean complete blinks increased by a factor of 1.7 from the spontaneous to the voluntary condition while mean incomplete blinks reduced significantly by a factor of 0.4. In both conditions, closing mean and peak velocities were always significantly greater and durations significantly lower than opening ones. When comparing the values for each condition, velocities and amplitudes for the voluntary condition were always greater than the corresponding values for spontaneous. CONCLUSION: Voluntary blinks revealed significant kinematic differences compared to spontaneous, thus supporting a different supranuclear pathway organization. This study presents a new method, based on image analysis, for the non-invasive kinematic characterization of blinking.


Assuntos
Piscadela , Processamento de Imagem Assistida por Computador , Fenômenos Biomecânicos , Humanos , Projetos de Pesquisa
4.
Cont Lens Anterior Eye ; 43(2): 103-114, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31445772

RESUMO

Every part of the human body is subject to aging, including the eye. An increased prevalence of dry eye disease with age is widely acknowledged. Aging threatens ocular surface homeostasis, altering the normal functioning of the lacrimal functional unit and potentially leading to signs and symptoms of dry eye. Additional age-related processes take place within the crystalline lens, leading to presbyopia and cataractogenesis. Correction strategies for presbyopia and cataracts may directly or indirectly challenge the ocular surface. Contact lenses disturb the normal structure of the tear film and can interact negatively with the ocular surface, further deteriorating an already unbalanced tear film in presbyopes, however, newer contact lens designs can overcome some of these issues. Moreover, cataract and corneal refractive surgeries sever corneal nerves and disrupt the corneal epithelium and ocular surface, which can influence surgical outcomes and aggravate dryness symptoms in older age groups. This review summarises the current understanding of how the invasive nature of contact lens wear and cataract and refractive surgery influence signs and symptoms of ocular dryness in an aging population.


Assuntos
Envelhecimento , Síndromes do Olho Seco/complicações , Presbiopia/fisiopatologia , Refração Ocular/fisiologia , Idoso , Progressão da Doença , Síndromes do Olho Seco/metabolismo , Humanos , Presbiopia/etiologia , Lágrimas/metabolismo
5.
J Ophthalmol ; 2017: 9707650, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29430305

RESUMO

OBJECTIVES: To describe the past 20 years' correction modalities for keratoconus and their visual outcomes and possible complications. METHODS: A review of the published literature related to the visual outcomes and possible complications in the context of keratoconus management using nonsurgical procedures for the last 20 years (glasses and contact lenses) was performed. Original articles that reported the outcome of any correction modalities of keratoconus management were reviewed. RESULTS: The most nonsurgical procedure used on keratoconus management is the contact lens fitting. Soft contact lenses and soft toric contact lenses, rigid gas-permeable contact lenses, piggyback contact lens system, hybrid contact lenses, and scleral and corneoscleral contact lenses form the contemporary range of available lens types for keratoconus management with contact lenses. All of them try to restore the vision, improve the quality of life, and delay surgical procedures in patients with this disease. Complications are derived from the intolerance of using contact lens, and the use of each depends on keratoconus severity. CONCLUSIONS: In the context of nonsurgical procedures, the use of contact lenses for the management of keratoconic patients represents a good alternative to restore vision and improve the quality of live in this population.

6.
Cont Lens Anterior Eye ; 38(5): 317-21, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25899637

RESUMO

PURPOSE: To evaluate the power profile within the optic zone of different designs of multifocal contact lenses (CLs) and to analyze how the effect of pupil size could impact on their optical performance. METHODS: The optical power distribution within the optic zones of multifocal CLs was measured by the Nimo TR1504 (LAMBDA-X, Belgium). The multifocal CLs under study were the Acuvue Bifocal, the Acuvue Oasys for Presbyopia, the PureVision Multifocal and the PureVision 2 for Presbyopia. Each design was considered in all their available addition powers. All lenses had a nominal power of -3.0D. At the same time, three lenses of each model were considered and five consecutive readings of each lens were performed. RESULTS: The results show that the PureVision Multifocal and the PureVision 2 for Presbyopia have aspheric power profiles. Both designs showed aspheric center-near designs with a smoother progression of the optical power in the PureVision 2 for Presbyopia. The Acuvue Bifocal and the Acuvue Oasys for Presbyopia are shown to have concentric alternating near and far zones. Apart from the refractive rings, the Acuvue Oasys for Presbyopia showed an increase in negative (or less positive) values toward the periphery of the lens. CONCLUSIONS: Besides the refraction, the knowledge of the power profiles of multifocal CLs and the effect of pupil size on the optical distribution of these lenses could be crucial to understand the performance of these designs when they are fitted.


Assuntos
Lentes de Contato/classificação , Iris/anatomia & histologia , Luz , Presbiopia/reabilitação , Refratometria/instrumentação , Espalhamento de Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
7.
Eye (Lond) ; 28(5): 614-20, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24556881

RESUMO

PURPOSE: To assess the optical performance of the new EnVista intraocular lens (IOL). MATERIALS AND METHODS: Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL's aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield once they are implanted, an average corneal-aberration pattern was juxtaposed to the in-vitro profiles and the same parameters were calculated again. RESULTS: For the IOL-only scenario (ie, without including the corneal factor), it was the EnVista IOL, which is aberration-free that showed the higher MTF, PSF values. This was followed by the other two aberration-free IOL models. However, when the effect of an average corneal pattern was also taken into consideration, the AcrySof IQ IOL SN60WF always outperformed the other neutral-asphericity IOLs. CONCLUSIONS: The in-vitro optical performance of the EnVista IOL was good, but it decreases substantially in a whole-eye scenario, when the wavefront profile of an average cornea is added. Other designs with different degrees of SA should be considered for this IOL in order to surpass these results.


Assuntos
Lentes Intraoculares/normas , Desenho de Prótese , Aberrações de Frente de Onda da Córnea , Humanos , Óptica e Fotônica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...